Austenitic stainless steel

Grade Chemical Composition Applicable Standard
(ASTM/ASME)
EN, etc. Characteristics Example of applications
304 18Cr-8Ni S30400 1.4301 Basic stainless steel grade General purpose for numerous applications
304H 18Cr-8Ni-High C S30409 1.4948 Basic stainless steel grade General purpose for numerous applications
304L 18Cr-8Ni-Low C S30403 1.4307 Intergranular corroison resistance General purpose for numerous applications
304N 18Cr-8Ni-N S30451 1.4315 High Strength  
304LN 18Cr-8Ni-Low C-N S30453 1.4311 Intergranular corroison resistance, high strength  
309H 22Cr-12Ni S30909 1.4829 Oxidation resistance Radiant tubes
309S 22Cr-12Ni S30908   Oxidation resistance Radiant tubes
310H 25Cr-20Ni S31009 1.4842 Oxidation resistancece Radiant tubes, boiler heater tubes
310S 25Cr-20Ni S31008   Oxidation resistancece Radiant tubes, boiler heater tubes
316 18Cr-12Ni-2Mo S31600 1.4401 Corrosion resistance LNG plant pipes, boilers and chemical industry tubes and pipes 
316H 18Cr-12Ni-2Mo-High C S31609 1.4918 Corrosion resistance LNG plant pipes, boilers and chemical industry tubes and pipes   
316L 18Cr-12Ni-2Mo-Low C S31603 1.4404 Corrosion resistance LNG plant pipes, boilers and chemical industry tubes and pipes 
316Ti 18Cr-12Ni-Mo-Ti S31635 1.4571 Intergranular corrosion resistance  
317 18Cr-12Ni-3Mo S31700   Pitting corrosion resistance Chemical tanler pipes
317L 18Cr-12Ni-3Mo-Low C S31703 1.4438 Pitting corrosion resistance Chemical tanler pipes
NEXAGE317CU 18Cr-16Ni-3.5Mo-4Cu S31730   Sulfuric and hydrochloric acid dew point corrosion resistance Exhaust gas pipes and heat exchanger tubes for sulfur fuel and boimass boilers 
NEXAGE317AP 17Cr-14Ni-3Mo-0.3Nb-N S31740
(ASME CC3038)
 
  • Polythionic acid stress corrosion crack resistance, weld crack resistance and stress relaxation crack resistance​​​​​
  • Naphthenic acid corrosion resistance
Petroleum refining plant furnace tubes
321 18Cr-9Ni-Ti S32100 1.4541 Intergranular corrosion resistance Chemical plant pipes
321H 18Cr-9Ni-Ti-High C S32109 1.4940 High-temperature strength Boiler heater tubes and reheater tubes
347 18Cr-9Ni-Nb S34700 1.4550 Intergranular corrosion resistance Chemical plant pipes and tubes
347H 18Cr-9Ni-Nb-High C S34709 1.4942 High-temperature strength Boiler heater tubes and reheater tubes
347AP 18Cr-10Ni-0.3Nb-Extra low C S34751  

Polythionic acid stress corrosion crack resistance, weld crack resistance and stress relaxation crack resistance

Petroleum refining plant furnace tubes
NEXAGE347AlPha 18Cr-11Ni-3Cu-Mo-Nb-B-N-Extra low C S34752
(ASME CC2984)
 
  • Polythionic acid stress corrosion crack resistance, weld crack resistance and stress relaxation crack resistance​​​​​
  • High-temperature strength
Petroleum refining plant furnace tubes
YUS270 20Cr-18Ni-6Mo-0.7Cu-0.2N- Low C S31254 1.4547 High pitting corrosion resistance
  • Seawater heat exchanger tubes
  • Food plant pipes handling high salinity
254SMO 20Cr-18Ni-6Mo-Cu-N S31254 1.4547 High pitting corrosion resistance Seawater heat exchanger tubes
HYDREXELTM 22Cr-13Ni-5Mn-2Mo-0.3N TPXM-19   Hydrogen embrittlement resistance and high strength High pressure gaseous hydrogen supply tubes for hydrogen stations
HYDLIQUIDTM 22Cr-13Ni-5Mn^2Mo-0.3N TPXM-19   Hydrogen embrittlement resistance and high low-temperature toughness Liquefied hydrogen, LNG plant pipes
310MoLN 25Cr-22Ni-2Mo-N S31050 1.4466 Intergranular corrosion resistance Urea reactor tubes

 

2. Ferritic, Maritensitic Stainless Steel

Ferritic Stainless Steel has higher Stress Corrosion Cracking  resistance than Type 304, widely used for heat exchanger tubes.

Ferritic, Maritensitic stainless steel

Grade Chemical Composition Applicable Standard
(ASTM/ASME)
EN, etc. Characteristics Example of applicatoins
430 18Cr S43000 1.016 Chloride corrosion resistance and stress corrosion crack resistance Water heater pipes
444 19Cr-2Mo-Ti/Nb S44400 1.4521 Chloride corrosion resistance and stress corrosion crack resistance Water heater pipes
YUS190 19Cr-2Mo-Ti-Nb-Extra Low C-Low N S44400 1.4521 Stress corrosion crack resistance (general corroison resistance at SUS304 or higher) 
  • Heat exchanger for various chemical plants
  • Small hot-water/steam boilers
446 25Cr-N S44600   Chloride corrosion resistance and stress corrosion crack resistance Water heater pipes

 

3. Duplex Stainless Steel

 Duplex stainless steel has higher strength, corrosion resistance (pitting ) than conventional austenitic stainless steels.

Duplex stainless steels

Grade Chemical Composition Applicable Standard
(ASTM/ASME)
EN, etc. Characteristics Example of applications
YUS2120 21Cr-2Ni-3Mn-Cu-N   JIS G3459
SUS821L1TP
High corrosion resistance(stress corrosion crack general corosion and crevice corrosion resistance) Heat exchanger for various chemical plants
YUS2351 23Cr-5Ni-1Mo-N   JIS G3459
SUS329J1TP
High corrosion resistance(stress corrosion crack general corosion and crevice corrosion resistance) Heat exchanger for various chemical plants
YUSTMDX1 22Cr-5Ni-3Mo-0.13Cu-Low C S31803 JIS G3463
SUS329J3LTB
High corrosion resistance(stress corrosion crack general corosion and crevice corrosion resistance) Heat exchanger for various chemical plants
329J3L 22Cr-5Ni-3Mo-0.15N S31803 1.4462
NORSOK
M-630/M-650
High strength, and High corrosion resistance Various heat exchanger tubes
DP11A 24Cr-4Ni-Mo-Cu-N     High corrosion resistance(stress corrosion crack general corosion and crevice corrosion resistance) Heat exchanger for various chemical plants
329J4L 25Cr-7Ni-3Mo-0.2N S31260   High strength, and High corrosion resistance Various heat exchanger tubes
S31500 18.5Cr-5Ni-2.7Mo S31500   High strength, and High corrosion resistance Various heat exchanger tubes
S32205 22.5Cr-6Ni-3Mo-0.2N S32205 1.4462
NORSOK
M-630/M-650
High strength, and High corrosion resistance Various heat exchanger tubes
S32750 25Cr-7Ni4Mo-0.3N S32750 1.4410
NORSOK
M-630/M-650
High strength, and High corrosion resistance Seawater desalination plant pipes
DP12 25Cr-7Ni-2.7Mo-W-N S31260   High corrosion resistance (Urea corrosion and stress corrosion crack resistance) Urea reactor tubes
DP3
DP3N
25Cr-7Ni-3.3Mo-W-N S31260   High corrosion resistance (Pitting corrosion, seawater and crevice corrosion resistance) Seawater heat exchanger tubes for various chemical plants
DP3W 25Cr-7Ni-3.2Mo-2W-N S39274
ASME CC2427
NORSOK
M-630/M-650
High corrosion resistance (Pitting corrosion, seawater and crevice corrosion resistance) Umbilical tubes and seawater heat exchanger tubes
DP28W 27.5Cr-7.7Ni-2.2W-Mo-N S32808
ASME CC2496
  High corrosion resistance (Urea corrosion and stress corrosion crack resistance) Urea reactor tubes

 

4. High-Ni, Ni-based Alloy

  •  High-Ni alloy like Alloy 825 has higher corrosion and strength in high temperature.
  • Ni-based alloy is applied to pipes and tubes for chemical plants where corrosion is particularly severe.

High-Ni, Ni-based alloy

Grade Chemical Composition Applicable Standard
(ASTM/ASME)
EN, etc. Characteristics Example of applications
800 20Cr-30Ni-Ti N08800 1.4558 High corrosion resistance  
800H 20Cr-30Ni-Ti-High C N08810 1.4876 High strength, high corrosion resistance Chemical plant heater and reheater tubes
904L 20Cr-25Ni-4.5Mo-Cu N08904 1.4539 High corrosion resistance Various heat exchanger tubes
28 27Cr-31Ni-3.5Mo-Cu N08028 1.4563 High corrosion resistance Various heat exchanger tubes
20 20Cr-35Ni-2Mo-3Cu-Nb N08020 2.4660 High corrosion resistance  
825 20Cr-42Ni-3Mo-2Cu-Ti N08825 2.4858 High corrosion resistance and stress corrosion crack resistanece Heat exchanger tubes fo petroleum refining
NEXAGEHR24 25Cr-38Ni-Mo-Si     Oxidation resistance, carburization resistance, and high temperature strength (700 to 1100 deg. C) Cracking tubes for ethylene plants
NEXAGE845 22.5Cr-47Ni-3Cu-6Mo-3.5W N06845
(ASME CC2794)
  Pitting corrosion resistance and acid resistance (sulfuric acid, hydrochliric acid, nitric acid, fomic acid etc.) Highly corrosion resistant pipes nad heat exchanger tubes for chemical industry
600 15Cr-8Fe-Ni base N06600 2.4816 Oxidation resistance Thermocouple protection tubes
601 23Cr-1.4Al-Ni base N06601 2.4581 Oxidation resistance and carburization resistance  
625 22Cr-9Mo-Ni base N06625 2.4856 High corrosion resistance and stress corrosion crack resistance  
690 29Cr-9Fe-Ni base N06690 2.4642 High corrosion resistance Steam generator tubes for PWR power plants
NEXAGE696 30Cr-60Ni-2Cu-1.5Si N06696
(ASME CC2652)
  Metal dusting corrosion resistance, caburization resistance, and high-temperature strength
  • Heating furnace pipes for synthetic gas plants
  • High- temperature pipes for direct reduction iron plants
C22 21Cr-13Mo-3W-Ni base N06022 2.4602 High acid resistance Heat exchanger tubes for chemical plants
276 15.5Cr-16Mo-5Fe-Ni base N10276 2.4819 High acid resistance Heat exchanger tubes for chemical plants
200 Ni (Annealed) N02200 2.4066 High corrosion resistance Heat exchanger tubes for caustic soda and hydrogen chloride plants
201 Ni-Low C N02201 2.4068 High corrosion resistance Heat exchanger tubes for caustic soda and hydrogen chloride plants
NEXAGE201 Ni-Low C-Nb N02201 2.4068 High strength (Easy handling) Heat exchanger tubes for caustic soda and hydrogen chloride plants